Tankless Technical Bulletin Vertical Venting Zero Clearance Demand Pumps Vertical Venting _ In the past we required to have a horizontal offset and a form of condensation collector in line or condensate tee for any of our Tankless water heater installations terminated with vertical vent configuration Effective with this notice Rheem will allow a straight vertical vent run off the top of the water heater provided that a vertical condensate collector as designed by the appropriate vent manufacturer is installed as close to the tankless water heater as possible All other considerations clearances and installation requirements as outlined in the Use and Care Manual must be met See our Tankless Application Drawing RTG11171 and RTG11172 for information and sugge ...