Honeywell - S8660

Below are all the different types of Honeywell. Select the device of your choice, to download the manual


Click here to download the manual

Contents

Honeywell INTERMITTENT PILOT MODULES S8600 S8610 S8660 S8670 APPLICATION These ignition modules provide ignition sequence flame monitoring and safety shutoff for intermittent pilot central furnaces and heating appliances S8600 and S8660 mod els provide up to 1 0 A pilot and 1 0 A main valve current rating S8610 and S8670 provide up to 1 0 A pilot and 2 0 A main valve current rating Minimum ambient temperature rating is 40 F 40 C Maximum ambient rating is 175 F 79 C for S8600 S8660 and for S8610 S8670 used with 1 0 A or less main valve Maximum ambient rating for S8610 S8670 used with 1 0 to 2 0 A main valve is 165 F 74 C See Table I for a summary of other differences between models TABLE 1 INTERMITTENT PILOT IGNITION MO ...