Troubleshooting Guide The following checklist will assist in the correction of most problems which you may encounter with your unit Before going through the checklist below refer to the connection and operating procedures Problem Cause Solution The POWER PROTECTOR indicator does not light up The fuse is blown Replace the fuse with a new one The ground lead is not securely connected Fasten the ground lead securely to a metal surface of the car The voltage going into the remote terminal is too low The connected master unit is not turned on Turn on the master unit The system employs too many amplifiers Use a relay Check the battery voltage 10 5 16 V The OVER CURRENT indicator lights up in red Turn off the ...