Maretron Vessel Monitoring amp Control Systems Installation Instructions LP 200012UL Gas Detector Instructions Please follow these instructions to connect the LP 200012UL to the NMEA 2000 network via a Maretron SIM100 Switch Indicator Module The wiring diagram appears in Figure 1 on the reverse side of this page The diagram shows a connection to channel 1 but connections to other channels are similar 1 Connect the LP 200012UL power terminals to a 12VDC supply that is independent of the NMEA 2000 network power supply as shown in Figure 1 Powering the unit separately from the NMEA 2000 network allows the detector to work even when the NMEA 2000 network is powered off 2 Connect the two alarm contact terminals to a free switch channel on the SIM100 The exam ...