Contents

Maretron Installation Instructions MS 1035 MS 1055 N MS 1075 MS 1085 N Magnetic Switches Instructions Please follow these instructions to connect any of the MS 1035 MS 1055 N MS 1075 or MS 1085 N to the NMEA 2000 network via a Maretron SIM100 Switch Indicator Module The wiring diagram appears in Figure 1 below The diagram shows a connection to channel 1 but connections to other channels are similar 1 Connect the two alarm contact terminals of the sensor portion of the magnetic switch to a free switch channel The example in Figure 1 shows the sensor portion of the magnetic switch connected to switch channel 1 with one wire connected to SW1A and the second wire connected to SW1B 2 Use a Maretron DSM250 display firmware 1 3 5 or higher the ...